Baite Burner Solenoid Coil 230V (MPN: BT-COIL-230V) is an industrial-duty component engineered for continuous factory operations, piping systems, and machinery maintenance in Kenya. Key verified ratings include Component Type: Solenoid Valve Replacement Coil, Compatible Burners: BAITE BT14, BT18, BT26 Series, Rated Supply Voltage: 220 - 240 V AC 50/60 Hz. Standard plant applications include BAITE BT14 Industrial Diesel Burners, BAITE BT18 High Capacity Oil Burners, BAITE BT26 Dual-Stage Oil Burners. Held at our STARNEX counter on Enterprise Road, Nairobi Industrial Area for immediate collection or same-day dispatch. When requesting a quotation, please specify required quantity, operating voltage/phase, pipe connection size, and delivery destination.
Baite Burner Solenoid Coil 230V
Baite Burner Solenoid Coil 230V (MPN: BT-COIL-230V) is an industrial-duty component engineered for continuous factory operations, piping systems, and machinery maintenance in Kenya. Key verified ratings include Component Type: Solenoid Valve Replacement Coil, Compatible Burners: BAITE BT14, BT18, BT26 Series, Rated Supply Voltage: 220 - 240 V AC 50/60 Hz. Standard plant applications include BAITE BT14 Industrial Diesel Burners, BAITE BT18 High Capacity Oil Burners, BAITE BT26 Dual-Stage Oil Burners. Held at our STARNEX counter on Enterprise Road, Nairobi Industrial Area for immediate collection or same-day dispatch. When requesting a quotation, please specify required quantity, operating voltage/phase, pipe connection size, and delivery destination.
Functional engineering application
The Baite Burner Solenoid Coil 230V is a high-reliability replacement electromagnetic coil designed for BAITE BT14, BT18, and BT26 industrial burner fuel pump solenoid cut-off valves. Encapsulated in heat-resistant epoxy resin, this coil delivers strong magnetic pull-in force to open fuel valve armatures under working pressures up to 25 bar. Operating on standard 220-240 V AC mains power with Class H (180°C) thermal insulation, the Baite solenoid coil resists coil burnout caused by high ambient boiler room temperatures. It is widely installed across tea processing factories, commercial bakeries, and industrial steam boilers in Kenya, Uganda, Tanzania, Rwanda, and Burundi.
Replacement 230V AC 50/60Hz electromagnetic solenoid coil for BAITE BT series oil burner fuel pump cut-off valves.
Quotation & fulfilment
Parametric technical attributes
| Generic BT-COIL-230V | |
| IDENTIFICATION | |
| Component Type | Baite Burner Solenoid Coil 230V |
| Manufacturer / Brand | Generic |
| Part Number (MPN) | BT-COIL-230V |
| Stock Keeping Unit (SKU) | GEN-SC-BAITE230V |
| TECHNICAL PARAMETERS | |
| Component Type | Solenoid Valve Replacement Coil |
| Compatible Burners | BAITE BT14, BT18, BT26 Series |
| Coil Height | 38.0 mm |
| Electrical Connector | 3-Pin DIN Plug / Terminal Block |
| Thermal Insulation Class | Class H (180 °C) |
| Enclosure Protection | IP 65 with sealing gasket |
| Duty Cycle | 100% ED Continuous Duty |
| Weight | 0.16 kg |
| PERFORMANCE & RATINGS | |
| Rated Supply Voltage | 220 - 240 V AC 50/60 Hz |
| Power Consumption | 9.0 W |
| Ambient Temperature Max | 60 °C |
| CONSTRUCTION & CONNECTION | |
| Armature Stem Diameter | Ø 13.2 mm Internal Bore |
| Encapsulation Material | High-Purity Epoxy Resin |
| COMPLIANCE & STANDARDS | |
| Origin | International OEM Standard |
| COMPLIANCE & LOGISTICS | |
| Stock Availability | On request |
System fitment & verified replacements
Interchangeable models
- Danfoss 240V 7W Solenoid Coil
- Suntec Oil Burner Solenoid Valve Assembly
Commonly installed on equipment from
Common questions on this part
This coil is designed for BAITE BT14, BT18, and BT26 series forced-draft oil burner pump solenoid valves.
Available at STARNEX Industrial Spares, SMK Business Center, Enterprise Road, Industrial Area, Nairobi.
Yes, we ship daily across East Africa to Kampala, Jinja, Dar es Salaam, Arusha, Mwanza, Kigali, and Bujumbura.
It features a standard 13.2 mm internal diameter bore to fit BAITE solenoid armature guide tubes.
Yes, if the coil is burnt out, the fuel valve cannot open, causing immediate burner safety lockout due to lack of fuel.
It features Class H (180°C) high-temperature insulation to prevent breakdown in hot boiler environments.
Yes, it is rated for 100% ED continuous duty cycles.
Yes, top-mounted coils slip off the armature tube once the retaining nut is removed, without opening oil piping.
Operates on standard 220-240 V AC 50/60 Hz mains power.
Measure coil resistance with a multimeter (typically 1.5 to 3.5 kΩ) or check for magnetic pull with a screwdriver tip when energized.
Yes, STARNEX stocks BAITE BT18/26 fuel pumps and accessories.
Yes, corporate discounts are available for tea factories and maintenance engineers.
Yes, counter pickup is available immediately at SMK Business Center, Enterprise Road.
Only a standard wrench or pliers to remove the top retaining nut.
Check the nameplate or stamped part number on your existing unit, along with operating parameters (e.g. dimensions, voltage, pressure rating, or connection size). You can share a photo of the nameplate directly via WhatsApp or our Request a Quote form, and our sales desk will confirm technical fitment, lead time, and pricing.