Multi-Probe Liquid Level Controller (MPN: BLX-LC-1100) is an industrial-duty component engineered for continuous factory operations, piping systems, and machinery maintenance in Kenya. Key verified ratings include Control Function Modes: Selectable: Water Supply (Filling) or Drainage (Emptying), Number of Probes Required: 3 Probes: Max (High Level), Min (Low Level), Common (Ground), Sensitivity Adjustment: Adjustable 5 kΩ to 100 kΩ (Continuous potentiometer). Standard plant applications include Overhead water tank automatic refilling from underground sumps, Submersible borehole pump run-dry protection in low-yield wells, Basement drainage sump and storm water pump automatic emptying. Held at our STARNEX counter on Enterprise Road, Nairobi Industrial Area for immediate collection or same-day dispatch. When requesting a quotation, please specify required quantity, operating voltage/phase, pipe connection size, and delivery destination.
Multi-Probe Liquid Level Controller
Multi-Probe Liquid Level Controller (MPN: BLX-LC-1100) is an industrial-duty component engineered for continuous factory operations, piping systems, and machinery maintenance in Kenya. Key verified ratings include Control Function Modes: Selectable: Water Supply (Filling) or Drainage (Emptying), Number of Probes Required: 3 Probes: Max (High Level), Min (Low Level), Common (Ground), Sensitivity Adjustment: Adjustable 5 kΩ to 100 kΩ (Continuous potentiometer). Standard plant applications include Overhead water tank automatic refilling from underground sumps, Submersible borehole pump run-dry protection in low-yield wells, Basement drainage sump and storm water pump automatic emptying. Held at our STARNEX counter on Enterprise Road, Nairobi Industrial Area for immediate collection or same-day dispatch. When requesting a quotation, please specify required quantity, operating voltage/phase, pipe connection size, and delivery destination.
Functional engineering application
The BLX-LC-1100 Multi-Probe Liquid Level Controller provides reliable, maintenance-free automatic level management for borehole water storage tanks, overhead commercial reservoirs, wastewater sumps, and industrial boilers in Kenya. Operating on the conductive liquid sensing principle, the controller detects liquid presence across three stainless steel electrode probes: Common (Ground), Low (Start/Stop threshold), and High (Stop/Start threshold). A front-panel rotary potentiometer adjusts sensing sensitivity from 5kΩ to 100kΩ, ensuring reliable detection across varied water types from pure mountain runoff to borehole mineral water and treated sewage effluent. To prevent galvanic corrosion and electrochemical scaling of the immersed probes, the sensing circuit energizes the electrodes with an isolated, ultra-low AC voltage (8V AC), ensuring years of trouble-free probe life.
DIN-rail mount conductive liquid level controller relay for 3 stainless probes, featuring adjustable sensitivity (5k-100kΩ), 8A SPDT output, low 8VAC probe voltage, and pump filling/emptying modes.
Quotation & fulfilment
Parametric technical attributes
| Generic BLX-LC-1100 | |
| IDENTIFICATION | |
| Component Type | Multi-Probe Liquid Level Controller |
| Manufacturer / Brand | Generic |
| Part Number (MPN) | BLX-LC-1100 |
| Stock Keeping Unit (SKU) | STX-BLX-BLXLC1100 |
| TECHNICAL PARAMETERS | |
| Control Function Modes | Selectable: Water Supply (Filling) or Drainage (Emptying) |
| Sensing Principle | Conductive Liquid Resistance via Immersed Electrode Probes |
| Number of Probes Required | 3 Probes: Max (High Level), Min (Low Level), Common (Ground) |
| Sensitivity Adjustment | Adjustable 5 kΩ to 100 kΩ (Continuous potentiometer) |
| Output Relay Rating | 1 x SPDT (1 NO + 1 NC), 8 A @ 250 V AC (Resistive) |
| Response Delay Time | < 100 ms (built-in wave slosh filtering delay) |
| Housing Dimensions | 36 mm wide (2 DIN modules) x 90 mm x 65 mm |
| PERFORMANCE & RATINGS | |
| Electrode Probe Voltage | 8 V AC (Isolated, prevents probe electrolysis) |
| Power Supply Voltage | 230 V AC ±10% (50/60 Hz) / 24V DC option |
| Power Consumption | < 3 VA |
| Operating Temperature | -10°C to +55°C |
| COMPLIANCE & STANDARDS | |
| Mounting Standard | Standard 35 mm DIN-Rail (EN 50022) |
| COMPLIANCE & LOGISTICS | |
| Stock Availability | On request |
System fitment & verified replacements
Interchangeable models
- Omron 61F
- Carlo Gavazzi CL
- Finder 72 Series
Commonly installed on equipment from
Common questions on this part
The BLX-LC-1100 provides both Normally Open (NO) and Normally Closed (NC) relay contacts. Connecting the pump contactor through the NC terminal configures filling mode (pump runs when tank is below Low probe and stops at High probe). Connecting through the NO terminal configures emptying mode.
Standard 316 stainless steel electrode rods with ceramic holders (such as the STARNEX STX-PRB-SS316) are suspended at the desired depths in the tank via single-core insulated cable.
Yes. Install two probes above the pump motor intake in the borehole; when the water table falls below the low probe, the controller de-energizes the pump starter to prevent dry running damage.
No. Conductive level controllers require conductive liquids (water, milk, wastewater, chemical solutions). Pure oils and diesel are non-conductive and require float switches or hydrostatic pressure sensors.
Yes. Level controllers and stainless steel probe sets are available off-the-shelf at STARNEX in Nairobi.