Molded Case Circuit Breaker (MCCB) is an industrial spare component used for Main incoming circuit breaker for factory distribution switchboards and MCCs. STARNEX Industrial Spares supplies this replacement component in Kenya with technical sourcing support across East Africa. Before ordering, confirm the required dimensions, connection standards, and equipment model with our technical sales team.
Molded Case Circuit Breaker (MCCB)
Molded Case Circuit Breaker (MCCB) is an industrial spare component used for Main incoming circuit breaker for factory distribution switchboards and MCCs. STARNEX Industrial Spares supplies this replacement component in Kenya with technical sourcing support across East Africa. Before ordering, confirm the required dimensions, connection standards, and equipment model with our technical sales team.
Functional engineering application
The Molded Case Circuit Breaker (MCCB) (MPN: BLX-MCCB-6000) is built for continuous-duty industrial piping, holding pressure, temperature, and cycling loads in factory installations across Kenya and East Africa.
Quotation & fulfilment
Parametric technical attributes
| Generic BLX-MCCB-6000 | |
| IDENTIFICATION | |
| Component Type | Molded Case Circuit Breaker (MCCB) |
| Manufacturer / Brand | Generic |
| Part Number (MPN) | BLX-MCCB-6000 |
| Stock Keeping Unit (SKU) | STX-BLX-BLXMCCB6000 |
| TECHNICAL PARAMETERS | |
| Frame Current Rating (In) | 250 A (Frame sizes 100A, 160A, 250A, 400A available) |
| Number of Poles | 3-Pole (3P) / 3-Phase |
| Ultimate Breaking Capacity (Icu) | 50 kA @ 415 V AC (IEC 60947-2) |
| Service Breaking Capacity (Ics) | 36 kA (75% Icu) @ 415 V AC |
| Trip Unit Technology | Thermal-Magnetic Trip Unit (TMD) |
| Overload Adjustment Range | Adjustable 0.8 to 1.0 x In (200A to 250A) |
| Short-Circuit Trip (Ii) | Fixed Instantaneous Magnetic 10 x In (2500 A) |
| Utilization Category | Category A (Selectivity non-delayed) |
| Mechanical / Electrical Life | Mechanical: 15,000 cycles; Electrical: 8,000 cycles |
| PERFORMANCE & RATINGS | |
| Rated Operational Voltage (Ue) | 415 V AC (50/60 Hz) |
| Rated Insulation Voltage (Ui) | 800 V AC |
| Impulse Withstand Voltage (Uimp) | 8 kV |
| CONSTRUCTION & CONNECTION | |
| Terminal Connections | Heavy tin-plated copper screw lugs with terminal phase barriers |
| COMPLIANCE & LOGISTICS | |
| Stock Availability | In Stock — Enterprise Rd, Nairobi |
| KRA Tax Status | Official KRA E-TIMS Tax Invoice Available |
System fitment & verified replacements
Verified interchangeable models
- Schneider Compact NSX
- ABB Tmax
- Chint NXM
- Siemens 3VA
Commonly installed on equipment from
Common questions on this part
On the front face below the toggle handle, a rotary dial allows continuous adjustment of the thermal overload trip threshold from 0.8 to 1.0 times the nominal current (e.g. 200A to 250A).
Yes. Each BLX-MCCB-6000 is supplied with snap-in high-dielectric interphase barrier plates that prevent accidental arcing or flashover between adjacent line and load terminals.
Yes. Internal accessory pockets accommodate snap-in auxiliary contacts (OF), alarm contacts (SD), and shunt trip coils (MX) for remote emergency tripping or automation feedback.
Yes. The breaker complies fully with IEC 60947-2 standards recognized by Kenya Bureau of Standards (KEBS) and Kenya Power.
Yes. STARNEX stocks 100A, 125A, 160A, 200A, 250A, and 400A MCCBs at our Enterprise Road trade counter for immediate collection.