LEO ACm300 3.0kW (4.0HP) Three-Phase Industrial Centrifugal Water Pump is an authentic LEO industrial component (Model/MPN: ACm300) engineered for continuous factory operations and machinery maintenance in Kenya and across East Africa. Key verified ratings include Model Code / MPN: ACm300, Rated Motor Power: 3.0 kW (4.0 HP), Electrical Supply: 380-415V, 50Hz, 3-Phase. Standard plant applications include Factory water transfer and circulating systems, Commercial building overhead tank booster supply, Agricultural crop irrigation and greenhouse watering. Held at our STARNEX counter on Enterprise Road, Nairobi Industrial Area for immediate collection or same-day dispatch. When requesting a quotation, please specify required quantity, operating voltage/phase, pipe connection size, and delivery destination.
LEO ACm300 3.0kW (4.0HP) Three-Phase Industrial Centrifugal Water Pump
LEO ACm300 3.0kW (4.0HP) Three-Phase Industrial Centrifugal Water Pump is an authentic LEO industrial component (Model/MPN: ACm300) engineered for continuous factory operations and machinery maintenance in Kenya and across East Africa. Key verified ratings include Model Code / MPN: ACm300, Rated Motor Power: 3.0 kW (4.0 HP), Electrical Supply: 380-415V, 50Hz, 3-Phase. Standard plant applications include Factory water transfer and circulating systems, Commercial building overhead tank booster supply, Agricultural crop irrigation and greenhouse watering. Held at our STARNEX counter on Enterprise Road, Nairobi Industrial Area for immediate collection or same-day dispatch. When requesting a quotation, please specify required quantity, operating voltage/phase, pipe connection size, and delivery destination.
Functional engineering application
OVERVIEW The LEO ACm300 is an industrial-grade 3.0kW (4.0HP) three-phase industrial centrifugal water pump designed for rigorous water handling operations across Kenyan industrial, commercial, and agricultural facilities. Engineered with precision hydraulic clearances and high-grade metallurgical components, this pump ensures stable hydraulic throughput, low acoustic signature, and long service life under fluctuating operating conditions. OPERATING PRINCIPLES AND HYDRAULIC DESIGN Equipped with an optimized cast brass impeller, the ACm300 efficiently converts mechanical shaft energy into hydraulic velocity and static pressure. With a maximum discharge head of 55 meters and peak throughput of 18.0 m3/h (300 L/min), the unit provides dependable pressure delivery. Port dimensions of 2" G suction and 2" G discharge ensure smooth fluid velocity with minimal internal friction loss. CONSTRUCTION, MATERIALS AND MOTOR SPECIFICATIONS - Pump Body: HT200 Cast Iron with anti-rust electrophoresis with electro-deposition anti-rust coating - Impeller: Cast Brass Impeller engineered for wear resistance - Mechanical Seal: Carbon / Ceramic / NBR providing positive shaft sealing without fluid weeping - Motor: Continuous duty induction motor (380-415V, 50Hz, 3-Phase), Class F insulation, IP44 ingress protection - Integrated Protection: Built-in thermal overload cut-out on single-phase windings; external overload relay recommended on three-phase installations KENYAN APPLICATION AND INSTALLATION GUIDELINES In East African operational settings, correct plumbing and electrical installation are vital for pump longevity: 1. Suction Plumbing: Install rigid suction piping of at least 2" G diameter. For suction lift duties (up to 8m), always fit a high-integrity foot valve with stainless steel strainer screen to prevent loss of prime. 2. Electrical Protection: Wire the 380-415V, 50Hz, 3-Phase motor through a dedicated motor circuit breaker or contactor with calibrated thermal overload protection. On sites prone to voltage sags, fit an electronic under/over-voltage monitoring relay. 3. Priming: Completely fill the pump wet end and suction line with clean water through the top priming plug before energizing the motor. Never run the pump dry. 4. Foundation: Anchor the pump securely to a level concrete plinth with anti-vibration mountings to avoid pipe stress and bearing misalignment. PREVENTIVE MAINTENANCE AND STARNEX SPARES SUPPORT Inspect mechanical seal faces and shaft bearings every 2,000 running hours or semi-annually. Lubricate bearings where applicable and clean suction strainers periodically. STARNEX Industrial Spares maintains direct inventory of genuine LEO replacement seals, O-rings, impellers, capacitors, and terminal boxes at our Enterprise Road trade counter in Nairobi.
Genuine LEO ACm300 3.0kW (4.0HP) three-phase industrial centrifugal water pump engineered for dependable continuous pumping. Delivers up to 18.0 m3/h (300 L/min) flow rate and 55m maximum head. Supplied in Kenya by STARNEX Industrial Spares with local stock and technical support.
Quotation & fulfilment
Parametric technical attributes
| LEO ACm300 | |
| IDENTIFICATION | |
| Component Type | LEO ACm300 3.0kW (4.0HP) Three-Phase Industrial Centrifugal Water Pump |
| Manufacturer / Brand | LEO |
| Part Number (MPN) | ACm300 |
| Stock Keeping Unit (SKU) | LEO-ACM300 |
| TECHNICAL PARAMETERS | |
| Model Code / MPN | ACm300 |
| Electrical Supply | 380-415V, 50Hz, 3-Phase |
| Maximum Head (Hmax) | 55 meters |
| Maximum Suction Lift | 8 meters |
| Ingress Protection & Insulation | IP44, Class F |
| PERFORMANCE & RATINGS | |
| Rated Motor Power | 3.0 kW (4.0 HP) |
| Maximum Flow Rate (Qmax) | 18.0 m³/h (300 L/min) |
| Maximum Working Pressure | 6.0 bar |
| Liquid Temperature Range | -10°C to +60°C |
| CONSTRUCTION & CONNECTION | |
| Suction Port Size | 2" G |
| Discharge Port Size | 2" G |
| Impeller Material | Cast Brass Impeller |
| Pump Body Material | HT200 Cast Iron with anti-rust electrophoresis |
| Mechanical Shaft Seal | Carbon / Ceramic / NBR |
| COMPLIANCE & LOGISTICS | |
| Stock Availability | In Stock - Enterprise Rd, Nairobi |
System fitment & verified replacements
Interchangeable models
Commonly installed on equipment from
Common questions on this part
The ACm300 operates on three-phase 380-415V at 50Hz, drawing balanced phase currents for high electrical efficiency and continuous duty industrial applications.
The ACm300 delivers up to 18.0 m3/h (300 L/min) and 55 meters head (5.5 bar), providing substantial throughput for factories and large estate irrigation.
A Direct-On-Line (DOL) magnetic starter with adjustable thermal overload relay (set to motor nameplate F.L.A., approx. 6.8A) and phase failure protection should be installed.
Yes, its Class F insulated motor and heavy cast iron construction are engineered for continuous industrial duty (S1 duty cycle) in ambient temperatures up to 40°C.
Check the nameplate or stamped part number on your existing unit, along with operating parameters (e.g. dimensions, voltage, pressure rating, or connection size). You can share a photo of the nameplate directly via WhatsApp or our Request a Quote form, and our sales desk will confirm technical fitment, lead time, and pricing.