Pixsys ATR244-12ABC Advanced PID Process & Temperature Controller is an industrial spare component used for Steam boiler modulating burner and feed water temperature loops. STARNEX Industrial Spares supplies and sources Pixsys spare parts for maintenance engineers, plant operators, and procurement teams in Kenya and East Africa. Before ordering, verify the manufacturer part number (MPN), voltage/pressure specifications, and equipment compatibility.
Pixsys ATR244-12ABC Advanced PID Process & Temperature Controller
Pixsys ATR244-12ABC Advanced PID Process & Temperature Controller is an industrial spare component used for Steam boiler modulating burner and feed water temperature loops. STARNEX Industrial Spares supplies and sources Pixsys spare parts for maintenance engineers, plant operators, and procurement teams in Kenya and East Africa. Before ordering, verify the manufacturer part number (MPN), voltage/pressure specifications, and equipment compatibility.
Functional engineering application
The Pixsys ATR244-12ABC Advanced PID Process & Temperature Controller (MPN: ATR244-12ABC) is built for continuous-duty industrial piping, holding pressure, temperature, and cycling loads in factory installations across Kenya and East Africa.
Quotation & fulfilment
Parametric technical attributes
| Pixsys ATR244-12ABC | |
| IDENTIFICATION | |
| Component Type | Pixsys ATR244-12ABC Advanced PID Process & Temperature Controller |
| Manufacturer / Brand | Pixsys |
| Part Number (MPN) | ATR244-12ABC |
| Stock Keeping Unit (SKU) | PIX-CTL-ATR244 |
| TECHNICAL PARAMETERS | |
| Manufacturer | Pixsys Electronics (Italy) |
| Series | Blue Line Advanced PID Controllers |
| Mounting & Cutout | Panel Mount 48 × 48 mm (1/16 DIN, Cutout 45 × 45 mm) |
| Dimensions & Depth | 48 mm (H) × 48 mm (W) × 105 mm (D) |
| Display Type | Dual High-Visibility LED: 4 Digits 0.52" (PV) + 5 Digits 0.30" (SP) |
| Analog Inputs | 1x 16-Bit Universal Programmable Input (Expandable to 2 loops on 23A/BC) |
| Supported Thermocouples | K, S, R, J, T, N, B (Cold Junction Comp. -25..85°C, ±0.2% F.S.) |
| Supported RTD / Thermistors | Pt100, Pt500, Pt1000, Ni100, PTC 1k, NTC 10k (B 3435K) |
| Linear Process Inputs | 0/4..20 mA (40k pts), 0..10 V (50k pts), 0..60 mV, Pot 1..150 kΩ |
| Current Transformer (CT/TA) Input | 1x 50 mA TA input (800 μs, 4096 pts) for Heater Break Alarm |
| Sampling Time | Programmable down to 2.1 ms (Up to 470 Hz) |
| Control Algorithms | ON/OFF with Hysteresis, P, PI, PID, PD Time-Proportional |
| Advanced Control Functions | Dual PID Heating/Cooling, Soft-Start Ramp (°C/h), Motorized Valve Logic, Loop Break Alarm |
| Analogue Output | 1x Selectable 4..20 mA or 0..10 V DC (40k pts, ±0.2% F.S.) Proportional Control or PV/SP Retransmission |
| Relay Outputs | 2 or 3x Relays 2 A @ 250 V AC Resistive Load |
| SSR Outputs | 2x SSR Drive Outputs: 12 / 24 V DC, 25 mA max |
| Auxiliary Sensor Supply | 12 / 24 V DC, 30 mA max for sensor loop power |
| Serial Communication | RS485 Modbus RTU (1200..115200 Baud, isolated) on -T models |
| Programming Interfaces | NFC Wireless (MyPixsys App) + Micro-USB Port (MyPixsysLab PC) |
| Enclosure Protection | Front IP65 (with gasket) / Enclosure IP20 |
| Operating Conditions | 0..45 °C ambient, 35..95% RH non-condensing |
| PERFORMANCE & RATINGS | |
| Power Supply | 24..230 V AC/DC ±10% 50/60 Hz (Galvanic Isolation 2.5 kV) |
| Power Consumption | 6 Watt / VA max |
| COMPLIANCE & LOGISTICS | |
| Stock Availability | In Stock — Enterprise Rd, Nairobi |
| KRA Tax Status | Official KRA E-TIMS Tax Invoice Available |
System fitment & verified replacements
Verified interchangeable models
- Honeywell Universal Digital Temperature Controller
- Pixsys ATR243 (Legacy Model)
Commonly installed on equipment from
Common questions on this part
A 50mA current transformer is installed around the heater element power conductor and wired to the ATR244 CT input terminals. During the heating cycle when the control output is active, the controller monitors the actual current. If the current drops below the programmed minimum threshold (indicating element open-circuit or burnout), the ATR244 immediately trips a Loop Break Alarm contact to alert the operator.
Yes. The ATR244-12ABC includes a dedicated analog output configurable in software for either 4..20 mA or 0..10 V DC with 40,000-point resolution (±0.2% F.S.). It can function as a proportional control output to position modulating steam valves and SCR thyristor packs, or as an isolated PV/SP retransmission signal to external PLCs or SCADA recorders.
Yes. STARNEX Industrial Spares maintains inventory of the Pixsys ATR244-12ABC at our Nairobi trade counter along Enterprise Road, available for same-day counter collection or dispatch across Kenya.
The ATR244 incorporates a front-bezel NFC antenna. Using the free MyPixsys smartphone app (Android and iOS), an engineer can read, duplicate, or modify complete parameter profiles simply by tapping the phone against the controller front panel—even when the instrument is unpowered in its box.